mirror of
https://github.com/MarlinFirmware/Configurations.git
synced 2025-07-13 09:48:01 -06:00
✨ MAX31865 Bed settings
MarlinFirmware/Marlin#27611 Co-Authored-By: ellensp <530024+ellensp@users.noreply.github.com>
This commit is contained in:
parent
2bc53e05a8
commit
6e2a97da53
754 changed files with 3393 additions and 1131 deletions
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -605,6 +605,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 5 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -659,6 +659,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -659,6 +659,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -605,6 +605,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 6 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -605,6 +605,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 6 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -607,6 +607,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -643,6 +643,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -614,6 +614,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -604,6 +604,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -611,6 +611,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -621,6 +621,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
|
@ -607,6 +607,10 @@
|
|||
#define MAX31865_SENSOR_OHMS_2 100
|
||||
#define MAX31865_CALIBRATION_OHMS_2 430
|
||||
#endif
|
||||
#if TEMP_SENSOR_IS_MAX_TC(BED)
|
||||
#define MAX31865_SENSOR_OHMS_BED 100
|
||||
#define MAX31865_CALIBRATION_OHMS_BED 430
|
||||
#endif
|
||||
|
||||
#if HAS_E_TEMP_SENSOR
|
||||
#define TEMP_RESIDENCY_TIME 10 // (seconds) Time to wait for hotend to "settle" in M109
|
||||
|
|
|
@ -177,6 +177,7 @@
|
|||
//#define MAX31865_SENSOR_WIRES_0 2 // (2-4) Number of wires for the probe connected to a MAX31865 board.
|
||||
//#define MAX31865_SENSOR_WIRES_1 2
|
||||
//#define MAX31865_SENSOR_WIRES_2 2
|
||||
//#define MAX31865_SENSOR_WIRES_BED 2
|
||||
|
||||
//#define MAX31865_50HZ_FILTER // Use a 50Hz filter instead of the default 60Hz.
|
||||
//#define MAX31865_USE_READ_ERROR_DETECTION // Treat value spikes (20°C delta in under 1s) as read errors.
|
||||
|
@ -188,6 +189,7 @@
|
|||
//#define MAX31865_WIRE_OHMS_0 0.95f // For 2-wire, set the wire resistances for more accurate readings.
|
||||
//#define MAX31865_WIRE_OHMS_1 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_2 0.0f
|
||||
//#define MAX31865_WIRE_OHMS_BED 0.0f
|
||||
|
||||
/**
|
||||
* Hephestos 2 24V heated bed upgrade kit.
|
||||
|
|
Some files were not shown because too many files have changed in this diff Show more
Loading…
Add table
Add a link
Reference in a new issue