@ -447,6 +447,10 @@
|
|||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_RESIDENCY_TIME 10 // (seconds) Time to wait for chamber to "settle" in M191
|
||||
#define TEMP_CHAMBER_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
|
@ -458,6 +462,7 @@
|
|||
#define HEATER_6_MINTEMP 5
|
||||
#define HEATER_7_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
|
@ -471,6 +476,7 @@
|
|||
#define HEATER_6_MAXTEMP 275
|
||||
#define HEATER_7_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
|
|
@ -144,12 +144,9 @@
|
|||
// Heated Chamber options
|
||||
//
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
// Make sure you define where your heater is connected, the following works on a BTT SKR 1.4 Turbo
|
||||
// using the secondary tool heater output. (FAN1 by default).
|
||||
//#define FAN1_PIN -1 // Remove the fan signal on pin P2_04 (SKR 1.4 Turbo specific)
|
||||
//#define HEATER_CHAMBER_PIN P2_04 // Chamber heater on/off pin (HE1 connector on SKR 1.4 Turbo)
|
||||
|
||||
//#define HEATER_CHAMBER_PIN P2_04 // Required heater on/off pin (example: SKR 1.4 Turbo HE1 plug)
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
//#define FAN1_PIN -1 // Remove the fan signal on pin P2_04 (example: SKR 1.4 Turbo HE1 plug)
|
||||
|
||||
//#define CHAMBER_FAN // Enable a fan on the chamber
|
||||
#if ENABLED(CHAMBER_FAN)
|
||||
|
|
Loading…