diff --git a/config/default/Configuration_adv.h b/config/default/Configuration_adv.h index 2f083417d9..d71593ad2d 100644 --- a/config/default/Configuration_adv.h +++ b/config/default/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/3DFabXYZ/Migbot/Configuration_adv.h b/config/examples/3DFabXYZ/Migbot/Configuration_adv.h index 181011edbd..c8ea67a7f5 100644 --- a/config/examples/3DFabXYZ/Migbot/Configuration_adv.h +++ b/config/examples/3DFabXYZ/Migbot/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/ADIMLab/Gantry v1/Configuration_adv.h b/config/examples/ADIMLab/Gantry v1/Configuration_adv.h index c18bd83a7f..aa63779632 100644 --- a/config/examples/ADIMLab/Gantry v1/Configuration_adv.h +++ b/config/examples/ADIMLab/Gantry v1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/ADIMLab/Gantry v2/Configuration_adv.h b/config/examples/ADIMLab/Gantry v2/Configuration_adv.h index b0cb628b29..90c13707f2 100644 --- a/config/examples/ADIMLab/Gantry v2/Configuration_adv.h +++ b/config/examples/ADIMLab/Gantry v2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AlephObjects/TAZ4/Configuration_adv.h b/config/examples/AlephObjects/TAZ4/Configuration_adv.h index a661ced061..3fc12ac534 100644 --- a/config/examples/AlephObjects/TAZ4/Configuration_adv.h +++ b/config/examples/AlephObjects/TAZ4/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Alfawise/U20-bltouch/Configuration_adv.h b/config/examples/Alfawise/U20-bltouch/Configuration_adv.h index 15a33b7cad..14397e269d 100644 --- a/config/examples/Alfawise/U20-bltouch/Configuration_adv.h +++ b/config/examples/Alfawise/U20-bltouch/Configuration_adv.h @@ -1972,21 +1972,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1995,7 +1995,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Alfawise/U20/Configuration_adv.h b/config/examples/Alfawise/U20/Configuration_adv.h index 5c3cfa2749..8c681ecef9 100644 --- a/config/examples/Alfawise/U20/Configuration_adv.h +++ b/config/examples/Alfawise/U20/Configuration_adv.h @@ -1962,21 +1962,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1985,7 +1985,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AliExpress/UM2pExt/Configuration_adv.h b/config/examples/AliExpress/UM2pExt/Configuration_adv.h index 32a11fa3d9..9f8166fff7 100644 --- a/config/examples/AliExpress/UM2pExt/Configuration_adv.h +++ b/config/examples/AliExpress/UM2pExt/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/A2/Configuration_adv.h b/config/examples/Anet/A2/Configuration_adv.h index 72bfb887d5..f1218be28d 100644 --- a/config/examples/Anet/A2/Configuration_adv.h +++ b/config/examples/Anet/A2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/A2plus/Configuration_adv.h b/config/examples/Anet/A2plus/Configuration_adv.h index 72bfb887d5..f1218be28d 100644 --- a/config/examples/Anet/A2plus/Configuration_adv.h +++ b/config/examples/Anet/A2plus/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/A6/Configuration_adv.h b/config/examples/Anet/A6/Configuration_adv.h index 0652b82a70..51839b1df1 100644 --- a/config/examples/Anet/A6/Configuration_adv.h +++ b/config/examples/Anet/A6/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/A8/Configuration_adv.h b/config/examples/Anet/A8/Configuration_adv.h index 98da4582ac..8ae7068dfd 100644 --- a/config/examples/Anet/A8/Configuration_adv.h +++ b/config/examples/Anet/A8/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/A8plus/Configuration_adv.h b/config/examples/Anet/A8plus/Configuration_adv.h index c2c990c2f3..24f848b4f8 100644 --- a/config/examples/Anet/A8plus/Configuration_adv.h +++ b/config/examples/Anet/A8plus/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/A9/Configuration_adv.h b/config/examples/Anet/A9/Configuration_adv.h index b0b29845af..77c7b76bee 100644 --- a/config/examples/Anet/A9/Configuration_adv.h +++ b/config/examples/Anet/A9/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/E10/Configuration_adv.h b/config/examples/Anet/E10/Configuration_adv.h index 391562b8b9..98bc8ec67d 100644 --- a/config/examples/Anet/E10/Configuration_adv.h +++ b/config/examples/Anet/E10/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/E16/BTT SKR 1.3/Configuration_adv.h b/config/examples/Anet/E16/BTT SKR 1.3/Configuration_adv.h index c0a15b7bd1..96339028dc 100644 --- a/config/examples/Anet/E16/BTT SKR 1.3/Configuration_adv.h +++ b/config/examples/Anet/E16/BTT SKR 1.3/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/E16/Stock/Configuration_adv.h b/config/examples/Anet/E16/Stock/Configuration_adv.h index a7b6d98dc7..a922887671 100644 --- a/config/examples/Anet/E16/Stock/Configuration_adv.h +++ b/config/examples/Anet/E16/Stock/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET4+/Configuration_adv.h b/config/examples/Anet/ET4+/Configuration_adv.h index 07f88d7273..4be4e1048d 100644 --- a/config/examples/Anet/ET4+/Configuration_adv.h +++ b/config/examples/Anet/ET4+/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET4-Pro/Configuration_adv.h b/config/examples/Anet/ET4-Pro/Configuration_adv.h index 07f88d7273..4be4e1048d 100644 --- a/config/examples/Anet/ET4-Pro/Configuration_adv.h +++ b/config/examples/Anet/ET4-Pro/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET4/Configuration_adv.h b/config/examples/Anet/ET4/Configuration_adv.h index a65dc942ec..6c249b3b4c 100644 --- a/config/examples/Anet/ET4/Configuration_adv.h +++ b/config/examples/Anet/ET4/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET4X/Configuration_adv.h b/config/examples/Anet/ET4X/Configuration_adv.h index a65dc942ec..6c249b3b4c 100644 --- a/config/examples/Anet/ET4X/Configuration_adv.h +++ b/config/examples/Anet/ET4X/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET5-Pro/Configuration_adv.h b/config/examples/Anet/ET5-Pro/Configuration_adv.h index 07945c473f..5ae06ae9ee 100644 --- a/config/examples/Anet/ET5-Pro/Configuration_adv.h +++ b/config/examples/Anet/ET5-Pro/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET5/Configuration_adv.h b/config/examples/Anet/ET5/Configuration_adv.h index 07945c473f..5ae06ae9ee 100644 --- a/config/examples/Anet/ET5/Configuration_adv.h +++ b/config/examples/Anet/ET5/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Anet/ET5X/Configuration_adv.h b/config/examples/Anet/ET5X/Configuration_adv.h index 07945c473f..5ae06ae9ee 100644 --- a/config/examples/Anet/ET5X/Configuration_adv.h +++ b/config/examples/Anet/ET5X/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AnyCubic/Chiron/Configuration_adv.h b/config/examples/AnyCubic/Chiron/Configuration_adv.h index 7e4a35a275..27d883e7cf 100644 --- a/config/examples/AnyCubic/Chiron/Configuration_adv.h +++ b/config/examples/AnyCubic/Chiron/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AnyCubic/Mega Zero 2.0/Anycubic V1/Configuration_adv.h b/config/examples/AnyCubic/Mega Zero 2.0/Anycubic V1/Configuration_adv.h index 2de7e1e523..9759d79805 100644 --- a/config/examples/AnyCubic/Mega Zero 2.0/Anycubic V1/Configuration_adv.h +++ b/config/examples/AnyCubic/Mega Zero 2.0/Anycubic V1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AnyCubic/Mega Zero/Anycubic V1/Configuration_adv.h b/config/examples/AnyCubic/Mega Zero/Anycubic V1/Configuration_adv.h index 447a83e1fc..53e8c8bca4 100644 --- a/config/examples/AnyCubic/Mega Zero/Anycubic V1/Configuration_adv.h +++ b/config/examples/AnyCubic/Mega Zero/Anycubic V1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AnyCubic/Mega Zero/BigTreeTech SKR Mini MZ V1.0/Configuration_adv.h b/config/examples/AnyCubic/Mega Zero/BigTreeTech SKR Mini MZ V1.0/Configuration_adv.h index 8aea4fc60a..5348f65cc0 100644 --- a/config/examples/AnyCubic/Mega Zero/BigTreeTech SKR Mini MZ V1.0/Configuration_adv.h +++ b/config/examples/AnyCubic/Mega Zero/BigTreeTech SKR Mini MZ V1.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AnyCubic/i3 Mega/Configuration_adv.h b/config/examples/AnyCubic/i3 Mega/Configuration_adv.h index d34627325f..acaafa2972 100644 --- a/config/examples/AnyCubic/i3 Mega/Configuration_adv.h +++ b/config/examples/AnyCubic/i3 Mega/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/AnyCubic/i3/Configuration_adv.h b/config/examples/AnyCubic/i3/Configuration_adv.h index e365b38bf8..1ed96aaeb8 100644 --- a/config/examples/AnyCubic/i3/Configuration_adv.h +++ b/config/examples/AnyCubic/i3/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/ArmEd/Configuration_adv.h b/config/examples/ArmEd/Configuration_adv.h index 905e475c3e..c4c8e8959a 100644 --- a/config/examples/ArmEd/Configuration_adv.h +++ b/config/examples/ArmEd/Configuration_adv.h @@ -1965,21 +1965,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1988,7 +1988,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Artillery/Genius/Configuration_adv.h b/config/examples/Artillery/Genius/Configuration_adv.h index e99f973474..c71b9f096b 100644 --- a/config/examples/Artillery/Genius/Configuration_adv.h +++ b/config/examples/Artillery/Genius/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Artillery/Sidewinder X1/Configuration_adv.h b/config/examples/Artillery/Sidewinder X1/Configuration_adv.h index e99f973474..c71b9f096b 100644 --- a/config/examples/Artillery/Sidewinder X1/Configuration_adv.h +++ b/config/examples/Artillery/Sidewinder X1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Artillery/Sidewinder X1_0.9_degree_BMG_E3D_V6/Configuration_adv.h b/config/examples/Artillery/Sidewinder X1_0.9_degree_BMG_E3D_V6/Configuration_adv.h index 0c57458805..afb96f5c59 100644 --- a/config/examples/Artillery/Sidewinder X1_0.9_degree_BMG_E3D_V6/Configuration_adv.h +++ b/config/examples/Artillery/Sidewinder X1_0.9_degree_BMG_E3D_V6/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Azteeg/X5GT/Configuration_adv.h b/config/examples/Azteeg/X5GT/Configuration_adv.h index 0f71e23a95..6337e6d8a6 100644 --- a/config/examples/Azteeg/X5GT/Configuration_adv.h +++ b/config/examples/Azteeg/X5GT/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h b/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h index d54044c2ad..ba5b6a4dbc 100644 --- a/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h +++ b/config/examples/BIBO/TouchX/cyclops/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BIBO/TouchX/default/Configuration_adv.h b/config/examples/BIBO/TouchX/default/Configuration_adv.h index de23488f96..c28477d6d3 100644 --- a/config/examples/BIBO/TouchX/default/Configuration_adv.h +++ b/config/examples/BIBO/TouchX/default/Configuration_adv.h @@ -1954,21 +1954,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1977,7 +1977,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BIQU/B1-BLTouch/Configuration_adv.h b/config/examples/BIQU/B1-BLTouch/Configuration_adv.h index ec5a93fc67..29f5131237 100644 --- a/config/examples/BIQU/B1-BLTouch/Configuration_adv.h +++ b/config/examples/BIQU/B1-BLTouch/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BIQU/B1/Configuration_adv.h b/config/examples/BIQU/B1/Configuration_adv.h index 952d8f3224..5d9b51e434 100644 --- a/config/examples/BIQU/B1/Configuration_adv.h +++ b/config/examples/BIQU/B1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BQ/Hephestos/Configuration_adv.h b/config/examples/BQ/Hephestos/Configuration_adv.h index 110ec37f6c..ca21f3c8f9 100644 --- a/config/examples/BQ/Hephestos/Configuration_adv.h +++ b/config/examples/BQ/Hephestos/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BQ/Hephestos_2/Configuration_adv.h b/config/examples/BQ/Hephestos_2/Configuration_adv.h index e22a9d5c14..fc7f41d19d 100644 --- a/config/examples/BQ/Hephestos_2/Configuration_adv.h +++ b/config/examples/BQ/Hephestos_2/Configuration_adv.h @@ -1969,21 +1969,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1992,7 +1992,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/BQ/WITBOX/Configuration_adv.h b/config/examples/BQ/WITBOX/Configuration_adv.h index 110ec37f6c..ca21f3c8f9 100644 --- a/config/examples/BQ/WITBOX/Configuration_adv.h +++ b/config/examples/BQ/WITBOX/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Cartesio/Configuration_adv.h b/config/examples/Cartesio/Configuration_adv.h index b96145c9fb..1e017e4e0c 100644 --- a/config/examples/Cartesio/Configuration_adv.h +++ b/config/examples/Cartesio/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 Mini/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Creality/CR-10 Mini/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index a314a20d21..d30bdbec0d 100644 --- a/config/examples/Creality/CR-10 Mini/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Creality/CR-10 Mini/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 Mini/CrealityV1/Configuration_adv.h b/config/examples/Creality/CR-10 Mini/CrealityV1/Configuration_adv.h index 9e709931ff..34aca1bcef 100644 --- a/config/examples/Creality/CR-10 Mini/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/CR-10 Mini/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 Mini/MEEB-3DP/Configuration_adv.h b/config/examples/Creality/CR-10 Mini/MEEB-3DP/Configuration_adv.h index 974740557e..d625c3aafb 100644 --- a/config/examples/Creality/CR-10 Mini/MEEB-3DP/Configuration_adv.h +++ b/config/examples/Creality/CR-10 Mini/MEEB-3DP/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 S4/CrealityV1/Configuration_adv.h b/config/examples/Creality/CR-10 S4/CrealityV1/Configuration_adv.h index 9da599f34c..a1aa8c259c 100644 --- a/config/examples/Creality/CR-10 S4/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/CR-10 S4/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 S5/CrealityV1/Configuration_adv.h b/config/examples/Creality/CR-10 S5/CrealityV1/Configuration_adv.h index 9da599f34c..a1aa8c259c 100644 --- a/config/examples/Creality/CR-10 S5/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/CR-10 S5/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 V2/Configuration_adv.h b/config/examples/Creality/CR-10 V2/Configuration_adv.h index e97f4af29b..169fa197cc 100644 --- a/config/examples/Creality/CR-10 V2/Configuration_adv.h +++ b/config/examples/Creality/CR-10 V2/Configuration_adv.h @@ -1964,21 +1964,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1987,7 +1987,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10 V3/Configuration_adv.h b/config/examples/Creality/CR-10 V3/Configuration_adv.h index d95325e483..db879b8aa0 100644 --- a/config/examples/Creality/CR-10 V3/Configuration_adv.h +++ b/config/examples/Creality/CR-10 V3/Configuration_adv.h @@ -1965,21 +1965,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1988,7 +1988,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Creality/CR-10/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index a31fdb2103..3fada0312e 100644 --- a/config/examples/Creality/CR-10/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Creality/CR-10/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10/CrealityV1/Configuration_adv.h b/config/examples/Creality/CR-10/CrealityV1/Configuration_adv.h index f108db78c1..ccdf6df7cf 100644 --- a/config/examples/Creality/CR-10/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/CR-10/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10S/BigTreeTech SKR 1.4 Turbo TMC2209/Configuration_adv.h b/config/examples/Creality/CR-10S/BigTreeTech SKR 1.4 Turbo TMC2209/Configuration_adv.h index 9a86babdd0..54c6978880 100644 --- a/config/examples/Creality/CR-10S/BigTreeTech SKR 1.4 Turbo TMC2209/Configuration_adv.h +++ b/config/examples/Creality/CR-10S/BigTreeTech SKR 1.4 Turbo TMC2209/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10S/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Creality/CR-10S/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index 1b3210a43f..1768dd2bb3 100644 --- a/config/examples/Creality/CR-10S/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Creality/CR-10S/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10S/BigTreeTech SKR Pro v1.2/Configuration_adv.h b/config/examples/Creality/CR-10S/BigTreeTech SKR Pro v1.2/Configuration_adv.h index cc18baf79f..daab5b8709 100644 --- a/config/examples/Creality/CR-10S/BigTreeTech SKR Pro v1.2/Configuration_adv.h +++ b/config/examples/Creality/CR-10S/BigTreeTech SKR Pro v1.2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-10S/CrealityV1/Configuration_adv.h b/config/examples/Creality/CR-10S/CrealityV1/Configuration_adv.h index 768e541b1a..13fa8d5528 100644 --- a/config/examples/Creality/CR-10S/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/CR-10S/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-20 Pro/Configuration_adv.h b/config/examples/Creality/CR-20 Pro/Configuration_adv.h index 326d0e7844..f6552f82d3 100644 --- a/config/examples/Creality/CR-20 Pro/Configuration_adv.h +++ b/config/examples/Creality/CR-20 Pro/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-20/Configuration_adv.h b/config/examples/Creality/CR-20/Configuration_adv.h index dae943f126..c9f1aa0d0e 100644 --- a/config/examples/Creality/CR-20/Configuration_adv.h +++ b/config/examples/Creality/CR-20/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-6 SE/Configuration_adv.h b/config/examples/Creality/CR-6 SE/Configuration_adv.h index 1769909171..f6fe974d94 100644 --- a/config/examples/Creality/CR-6 SE/Configuration_adv.h +++ b/config/examples/Creality/CR-6 SE/Configuration_adv.h @@ -1962,21 +1962,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1985,7 +1985,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/CR-8/Configuration_adv.h b/config/examples/Creality/CR-8/Configuration_adv.h index 6b43731e08..c7a946fb02 100644 --- a/config/examples/Creality/CR-8/Configuration_adv.h +++ b/config/examples/Creality/CR-8/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-2/Configuration_adv.h b/config/examples/Creality/Ender-2/Configuration_adv.h index 3312cd66ef..272063673a 100644 --- a/config/examples/Creality/Ender-2/Configuration_adv.h +++ b/config/examples/Creality/Ender-2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Max/Configuration_adv.h b/config/examples/Creality/Ender-3 Max/Configuration_adv.h index 1f885d6d59..3f7dc9cb46 100644 --- a/config/examples/Creality/Ender-3 Max/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Max/Configuration_adv.h @@ -1962,21 +1962,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1985,7 +1985,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR 1.4 Turbo/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR 1.4 Turbo/Configuration_adv.h index 82349eaf5f..6d7a5b5cb7 100644 --- a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR 1.4 Turbo/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR 1.4 Turbo/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h index 8e03c4eb94..939e0f9e4b 100644 --- a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h index 2b8445a3ea..d31f6298c3 100644 --- a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index f666172776..009efb01cf 100644 --- a/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/CrealityV1/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/CrealityV1/Configuration_adv.h index 8033549a9f..ce4c32a723 100644 --- a/config/examples/Creality/Ender-3 Pro/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/CrealityV422/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/CrealityV422/Configuration_adv.h index 7221b1c110..586ad0e50f 100644 --- a/config/examples/Creality/Ender-3 Pro/CrealityV422/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/CrealityV422/Configuration_adv.h @@ -1962,21 +1962,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1985,7 +1985,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 Pro/CrealityV427/Configuration_adv.h b/config/examples/Creality/Ender-3 Pro/CrealityV427/Configuration_adv.h index 0d8b64adb9..c2cea96822 100644 --- a/config/examples/Creality/Ender-3 Pro/CrealityV427/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 Pro/CrealityV427/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3 V2/Configuration_adv.h b/config/examples/Creality/Ender-3 V2/Configuration_adv.h index cb33edcd1c..969b8e83fa 100644 --- a/config/examples/Creality/Ender-3 V2/Configuration_adv.h +++ b/config/examples/Creality/Ender-3 V2/Configuration_adv.h @@ -1962,21 +1962,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1985,7 +1985,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech E3 RRF/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech E3 RRF/Configuration_adv.h index 4c8d89ea18..eff64003f8 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech E3 RRF/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech E3 RRF/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR 1.4/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR 1.4/Configuration_adv.h index 9eb26f72bb..e5fb97cb9e 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR 1.4/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR 1.4/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/2-into-1 Hotend/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/2-into-1 Hotend/Configuration_adv.h index 521d51dcd9..1b8ebf63fa 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/2-into-1 Hotend/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/2-into-1 Hotend/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Dual Z/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Dual Z/Configuration_adv.h index f4483e0ba2..7c17c1aabf 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Dual Z/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Dual Z/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Single Extruder/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Single Extruder/Configuration_adv.h index 521d51dcd9..1b8ebf63fa 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Single Extruder/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR E3 Turbo/Single Extruder/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR E3-DIP V1.1/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR E3-DIP V1.1/Configuration_adv.h index 68336edacf..78a27e0006 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR E3-DIP V1.1/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR E3-DIP V1.1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h index 8129423826..6eaa3b9322 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h index 480c9d04bd..d9dfdeaa34 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index ca02da5f34..06997ba5de 100644 --- a/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/CrealityV1/Configuration_adv.h b/config/examples/Creality/Ender-3/CrealityV1/Configuration_adv.h index 419302bc72..75ac1df0e4 100644 --- a/config/examples/Creality/Ender-3/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/CrealityV422/Configuration_adv.h b/config/examples/Creality/Ender-3/CrealityV422/Configuration_adv.h index 419302bc72..75ac1df0e4 100644 --- a/config/examples/Creality/Ender-3/CrealityV422/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/CrealityV422/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/CrealityV427/Configuration_adv.h b/config/examples/Creality/Ender-3/CrealityV427/Configuration_adv.h index 4416498703..f096755040 100644 --- a/config/examples/Creality/Ender-3/CrealityV427/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/CrealityV427/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/BLTouch/Configuration_adv.h b/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/BLTouch/Configuration_adv.h index cd7302d2da..0018df603a 100644 --- a/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/BLTouch/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/BLTouch/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/base/Configuration_adv.h b/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/base/Configuration_adv.h index cd7302d2da..0018df603a 100644 --- a/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/base/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/FYSETC Cheetah 1.2/base/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/FYSETC Cheetah/BLTouch/Configuration_adv.h b/config/examples/Creality/Ender-3/FYSETC Cheetah/BLTouch/Configuration_adv.h index cd7302d2da..0018df603a 100644 --- a/config/examples/Creality/Ender-3/FYSETC Cheetah/BLTouch/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/FYSETC Cheetah/BLTouch/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/FYSETC Cheetah/base/Configuration_adv.h b/config/examples/Creality/Ender-3/FYSETC Cheetah/base/Configuration_adv.h index cd7302d2da..0018df603a 100644 --- a/config/examples/Creality/Ender-3/FYSETC Cheetah/base/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/FYSETC Cheetah/base/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/MEEB-3DP/Configuration_adv.h b/config/examples/Creality/Ender-3/MEEB-3DP/Configuration_adv.h index 364c3cfe12..9c69b5e316 100644 --- a/config/examples/Creality/Ender-3/MEEB-3DP/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/MEEB-3DP/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/MKS Robin E3/V1.0/Configuration_adv.h b/config/examples/Creality/Ender-3/MKS Robin E3/V1.0/Configuration_adv.h index 9acfbbf6a9..2dd27d25eb 100644 --- a/config/examples/Creality/Ender-3/MKS Robin E3/V1.0/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/MKS Robin E3/V1.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/MKS Robin E3/V1.1/Configuration_adv.h b/config/examples/Creality/Ender-3/MKS Robin E3/V1.1/Configuration_adv.h index 2f1899bf3a..0b7923717d 100644 --- a/config/examples/Creality/Ender-3/MKS Robin E3/V1.1/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/MKS Robin E3/V1.1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-3/MKS Robin E3P/Configuration_adv.h b/config/examples/Creality/Ender-3/MKS Robin E3P/Configuration_adv.h index 0fc5684cb9..82f42745cf 100644 --- a/config/examples/Creality/Ender-3/MKS Robin E3P/Configuration_adv.h +++ b/config/examples/Creality/Ender-3/MKS Robin E3P/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-4/Configuration_adv.h b/config/examples/Creality/Ender-4/Configuration_adv.h index 1f5dadceb6..977ee4ae3c 100644 --- a/config/examples/Creality/Ender-4/Configuration_adv.h +++ b/config/examples/Creality/Ender-4/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Plus/Configuration_adv.h b/config/examples/Creality/Ender-5 Plus/Configuration_adv.h index f396207a17..cef7999853 100644 --- a/config/examples/Creality/Ender-5 Plus/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Plus/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h index e25eddda81..3fbfcceff9 100644 --- a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo/Configuration_adv.h index b32a2a249b..29a7969115 100644 --- a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR E3 Turbo/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h index 1a22f0c52c..ae2724ce03 100644 --- a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 2.0 with BLTouch/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 2.0 with BLTouch/Configuration_adv.h index 75f710db06..c947cc4588 100644 --- a/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 2.0 with BLTouch/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/BigTreeTech SKR Mini E3 2.0 with BLTouch/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/CrealityV1/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/CrealityV1/Configuration_adv.h index 76756625d2..fe7e60c8dc 100644 --- a/config/examples/Creality/Ender-5 Pro/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/CrealityV422/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/CrealityV422/Configuration_adv.h index 01cd6e4178..fd1eebddbd 100644 --- a/config/examples/Creality/Ender-5 Pro/CrealityV422/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/CrealityV422/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5 Pro/CrealityV427/Configuration_adv.h b/config/examples/Creality/Ender-5 Pro/CrealityV427/Configuration_adv.h index 76756625d2..fe7e60c8dc 100644 --- a/config/examples/Creality/Ender-5 Pro/CrealityV427/Configuration_adv.h +++ b/config/examples/Creality/Ender-5 Pro/CrealityV427/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/BigTreeTech SKR 1.4 Turbo (TMC2209)/Configuration_adv.h b/config/examples/Creality/Ender-5/BigTreeTech SKR 1.4 Turbo (TMC2209)/Configuration_adv.h index 4da39d4d16..488edafb60 100644 --- a/config/examples/Creality/Ender-5/BigTreeTech SKR 1.4 Turbo (TMC2209)/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/BigTreeTech SKR 1.4 Turbo (TMC2209)/Configuration_adv.h @@ -1965,21 +1965,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1988,7 +1988,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h b/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h index e25eddda81..3fbfcceff9 100644 --- a/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo with BLTouch/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo/Configuration_adv.h b/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo/Configuration_adv.h index b32a2a249b..29a7969115 100644 --- a/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/BigTreeTech SKR E3 Turbo/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h b/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h index 480c9d04bd..d9dfdeaa34 100644 --- a/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 1.2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index 4ab4123d19..378b2f7fe1 100644 --- a/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/CrealityV1/Configuration_adv.h b/config/examples/Creality/Ender-5/CrealityV1/Configuration_adv.h index b5acb5d8fd..1c80a75f63 100644 --- a/config/examples/Creality/Ender-5/CrealityV1/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/CrealityV1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-5/CrealityV427/Configuration_adv.h b/config/examples/Creality/Ender-5/CrealityV427/Configuration_adv.h index b5acb5d8fd..1c80a75f63 100644 --- a/config/examples/Creality/Ender-5/CrealityV427/Configuration_adv.h +++ b/config/examples/Creality/Ender-5/CrealityV427/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Creality/Ender-6/Configuration_adv.h b/config/examples/Creality/Ender-6/Configuration_adv.h index a9a1555dc7..3c3e5a2c5d 100644 --- a/config/examples/Creality/Ender-6/Configuration_adv.h +++ b/config/examples/Creality/Ender-6/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Dagoma/Disco Ultimate/Configuration_adv.h b/config/examples/Dagoma/Disco Ultimate/Configuration_adv.h index 540eaf610a..89fd8a60aa 100644 --- a/config/examples/Dagoma/Disco Ultimate/Configuration_adv.h +++ b/config/examples/Dagoma/Disco Ultimate/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Daycom/3DP-100/Configuration_adv.h b/config/examples/Daycom/3DP-100/Configuration_adv.h index 61802f84d4..5efd9af486 100644 --- a/config/examples/Daycom/3DP-100/Configuration_adv.h +++ b/config/examples/Daycom/3DP-100/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/EXP3D/Imprimante multifonction/Configuration_adv.h b/config/examples/EXP3D/Imprimante multifonction/Configuration_adv.h index 2032c79940..0ca22dd2d3 100644 --- a/config/examples/EXP3D/Imprimante multifonction/Configuration_adv.h +++ b/config/examples/EXP3D/Imprimante multifonction/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Einstart-S/Configuration_adv.h b/config/examples/Einstart-S/Configuration_adv.h index bef15353df..8a7b3521ff 100644 --- a/config/examples/Einstart-S/Configuration_adv.h +++ b/config/examples/Einstart-S/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Eryone/Thinker SE/Configuration_adv.h b/config/examples/Eryone/Thinker SE/Configuration_adv.h index 82a71b8263..3a0f803319 100644 --- a/config/examples/Eryone/Thinker SE/Configuration_adv.h +++ b/config/examples/Eryone/Thinker SE/Configuration_adv.h @@ -1967,21 +1967,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1990,7 +1990,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Eryone/Thinker V2/Configuration_adv.h b/config/examples/Eryone/Thinker V2/Configuration_adv.h index af9409a87c..2bb146bd36 100644 --- a/config/examples/Eryone/Thinker V2/Configuration_adv.h +++ b/config/examples/Eryone/Thinker V2/Configuration_adv.h @@ -1967,21 +1967,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1990,7 +1990,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FYSETC/AIO_II/Configuration_adv.h b/config/examples/FYSETC/AIO_II/Configuration_adv.h index d6f17acaee..1a994e5f2b 100644 --- a/config/examples/FYSETC/AIO_II/Configuration_adv.h +++ b/config/examples/FYSETC/AIO_II/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FYSETC/F6_13/Configuration_adv.h b/config/examples/FYSETC/F6_13/Configuration_adv.h index ece5342e12..22e7d90c03 100644 --- a/config/examples/FYSETC/F6_13/Configuration_adv.h +++ b/config/examples/FYSETC/F6_13/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FYSETC/S6/Configuration_adv.h b/config/examples/FYSETC/S6/Configuration_adv.h index 0cc0d397f5..05b3395bf7 100644 --- a/config/examples/FYSETC/S6/Configuration_adv.h +++ b/config/examples/FYSETC/S6/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Felix/DUAL/Configuration_adv.h b/config/examples/Felix/DUAL/Configuration_adv.h index ae890695a4..d3b28d2494 100644 --- a/config/examples/Felix/DUAL/Configuration_adv.h +++ b/config/examples/Felix/DUAL/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Felix/Single/Configuration_adv.h b/config/examples/Felix/Single/Configuration_adv.h index ae890695a4..d3b28d2494 100644 --- a/config/examples/Felix/Single/Configuration_adv.h +++ b/config/examples/Felix/Single/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FlashForge/Creator 2X/Configuration_adv.h b/config/examples/FlashForge/Creator 2X/Configuration_adv.h index b388ab7b68..8cb3d451f8 100644 --- a/config/examples/FlashForge/Creator 2X/Configuration_adv.h +++ b/config/examples/FlashForge/Creator 2X/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FlashForge/CreatorPro/Configuration_adv.h b/config/examples/FlashForge/CreatorPro/Configuration_adv.h index 0fef621f0d..653d6bfdfb 100644 --- a/config/examples/FlashForge/CreatorPro/Configuration_adv.h +++ b/config/examples/FlashForge/CreatorPro/Configuration_adv.h @@ -1960,21 +1960,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1983,7 +1983,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FlyingBear/P905H/Configuration_adv.h b/config/examples/FlyingBear/P905H/Configuration_adv.h index 115f266181..6fb1b8a416 100644 --- a/config/examples/FlyingBear/P905H/Configuration_adv.h +++ b/config/examples/FlyingBear/P905H/Configuration_adv.h @@ -1964,21 +1964,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1987,7 +1987,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FoamCutter/Configuration_adv.h b/config/examples/FoamCutter/Configuration_adv.h index 0f71e23a95..6337e6d8a6 100644 --- a/config/examples/FoamCutter/Configuration_adv.h +++ b/config/examples/FoamCutter/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/FolgerTech/i3-2020/Configuration_adv.h b/config/examples/FolgerTech/i3-2020/Configuration_adv.h index b2a5705ee1..b075f7b85c 100644 --- a/config/examples/FolgerTech/i3-2020/Configuration_adv.h +++ b/config/examples/FolgerTech/i3-2020/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Formbot/Raptor/Configuration_adv.h b/config/examples/Formbot/Raptor/Configuration_adv.h index 1fc982b945..00d8a9fdde 100644 --- a/config/examples/Formbot/Raptor/Configuration_adv.h +++ b/config/examples/Formbot/Raptor/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Formbot/T_Rex_2+/Configuration_adv.h b/config/examples/Formbot/T_Rex_2+/Configuration_adv.h index 77740f5204..500b2ab76a 100644 --- a/config/examples/Formbot/T_Rex_2+/Configuration_adv.h +++ b/config/examples/Formbot/T_Rex_2+/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Formbot/T_Rex_3/Configuration_adv.h b/config/examples/Formbot/T_Rex_3/Configuration_adv.h index bc2c41927d..3bbdb5b50b 100644 --- a/config/examples/Formbot/T_Rex_3/Configuration_adv.h +++ b/config/examples/Formbot/T_Rex_3/Configuration_adv.h @@ -1965,21 +1965,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1988,7 +1988,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A10/Configuration_adv.h b/config/examples/Geeetech/A10/Configuration_adv.h index 1e4433e1a9..1262e75bbc 100644 --- a/config/examples/Geeetech/A10/Configuration_adv.h +++ b/config/examples/Geeetech/A10/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A10D/Configuration_adv.h b/config/examples/Geeetech/A10D/Configuration_adv.h index 4c6361b22e..554d84b920 100644 --- a/config/examples/Geeetech/A10D/Configuration_adv.h +++ b/config/examples/Geeetech/A10D/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A10M/Configuration_adv.h b/config/examples/Geeetech/A10M/Configuration_adv.h index 27de27d11a..ec6b1acc39 100644 --- a/config/examples/Geeetech/A10M/Configuration_adv.h +++ b/config/examples/Geeetech/A10M/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A10PRO/Configuration_adv.h b/config/examples/Geeetech/A10PRO/Configuration_adv.h index 1e4433e1a9..1262e75bbc 100644 --- a/config/examples/Geeetech/A10PRO/Configuration_adv.h +++ b/config/examples/Geeetech/A10PRO/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A10T/Configuration_adv.h b/config/examples/Geeetech/A10T/Configuration_adv.h index 27de27d11a..ec6b1acc39 100644 --- a/config/examples/Geeetech/A10T/Configuration_adv.h +++ b/config/examples/Geeetech/A10T/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A20/Configuration_adv.h b/config/examples/Geeetech/A20/Configuration_adv.h index fbbaf8916e..6b6c31430b 100644 --- a/config/examples/Geeetech/A20/Configuration_adv.h +++ b/config/examples/Geeetech/A20/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A20M/Configuration_adv.h b/config/examples/Geeetech/A20M/Configuration_adv.h index fbbaf8916e..6b6c31430b 100644 --- a/config/examples/Geeetech/A20M/Configuration_adv.h +++ b/config/examples/Geeetech/A20M/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A20T/Configuration_adv.h b/config/examples/Geeetech/A20T/Configuration_adv.h index fbbaf8916e..6b6c31430b 100644 --- a/config/examples/Geeetech/A20T/Configuration_adv.h +++ b/config/examples/Geeetech/A20T/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A30/Configuration_adv.h b/config/examples/Geeetech/A30/Configuration_adv.h index 8ee6631f95..9a40273af3 100644 --- a/config/examples/Geeetech/A30/Configuration_adv.h +++ b/config/examples/Geeetech/A30/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A30M/Configuration_adv.h b/config/examples/Geeetech/A30M/Configuration_adv.h index 8ee6631f95..9a40273af3 100644 --- a/config/examples/Geeetech/A30M/Configuration_adv.h +++ b/config/examples/Geeetech/A30M/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/A30T/Configuration_adv.h b/config/examples/Geeetech/A30T/Configuration_adv.h index 8ee6631f95..9a40273af3 100644 --- a/config/examples/Geeetech/A30T/Configuration_adv.h +++ b/config/examples/Geeetech/A30T/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/D200/Configuration_adv.h b/config/examples/Geeetech/D200/Configuration_adv.h index 74fd657763..88fe0982ac 100644 --- a/config/examples/Geeetech/D200/Configuration_adv.h +++ b/config/examples/Geeetech/D200/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/Duplicator5/Configuration_adv.h b/config/examples/Geeetech/Duplicator5/Configuration_adv.h index 0cc0d397f5..05b3395bf7 100644 --- a/config/examples/Geeetech/Duplicator5/Configuration_adv.h +++ b/config/examples/Geeetech/Duplicator5/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/E180/Configuration_adv.h b/config/examples/Geeetech/E180/Configuration_adv.h index 8ee6631f95..9a40273af3 100644 --- a/config/examples/Geeetech/E180/Configuration_adv.h +++ b/config/examples/Geeetech/E180/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/M201/Configuration_adv.h b/config/examples/Geeetech/M201/Configuration_adv.h index 74fd657763..88fe0982ac 100644 --- a/config/examples/Geeetech/M201/Configuration_adv.h +++ b/config/examples/Geeetech/M201/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/MeCreator2/Configuration_adv.h b/config/examples/Geeetech/MeCreator2/Configuration_adv.h index cbf1f2067a..c887320dc1 100644 --- a/config/examples/Geeetech/MeCreator2/Configuration_adv.h +++ b/config/examples/Geeetech/MeCreator2/Configuration_adv.h @@ -1960,21 +1960,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1983,7 +1983,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/Me_creator/Configuration_adv.h b/config/examples/Geeetech/Me_creator/Configuration_adv.h index 0cc0d397f5..05b3395bf7 100644 --- a/config/examples/Geeetech/Me_creator/Configuration_adv.h +++ b/config/examples/Geeetech/Me_creator/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/Me_ducer/Configuration_adv.h b/config/examples/Geeetech/Me_ducer/Configuration_adv.h index 7ed4bdc82d..a60787bb09 100644 --- a/config/examples/Geeetech/Me_ducer/Configuration_adv.h +++ b/config/examples/Geeetech/Me_ducer/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/PI3A PRO/Configuration_adv.h b/config/examples/Geeetech/PI3A PRO/Configuration_adv.h index 37a5db18d6..fc178617c8 100644 --- a/config/examples/Geeetech/PI3A PRO/Configuration_adv.h +++ b/config/examples/Geeetech/PI3A PRO/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h b/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h index 1e4433e1a9..1262e75bbc 100644 --- a/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h +++ b/config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h b/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h index 1e4433e1a9..1262e75bbc 100644 --- a/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h +++ b/config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/HMS434/Configuration_adv.h b/config/examples/HMS434/Configuration_adv.h index 54d70a775a..ffa5595691 100644 --- a/config/examples/HMS434/Configuration_adv.h +++ b/config/examples/HMS434/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Infitary/i3-M508/Configuration_adv.h b/config/examples/Infitary/i3-M508/Configuration_adv.h index 24e6056baa..91b3e7d702 100644 --- a/config/examples/Infitary/i3-M508/Configuration_adv.h +++ b/config/examples/Infitary/i3-M508/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Intamsys/FunmatHT 4988/Configuration_adv.h b/config/examples/Intamsys/FunmatHT 4988/Configuration_adv.h index cb4fa6f2c0..a699e5aa08 100644 --- a/config/examples/Intamsys/FunmatHT 4988/Configuration_adv.h +++ b/config/examples/Intamsys/FunmatHT 4988/Configuration_adv.h @@ -1960,21 +1960,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1983,7 +1983,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/JGAurora/A1/Configuration_adv.h b/config/examples/JGAurora/A1/Configuration_adv.h index 9e2338339b..cb33f28ab2 100644 --- a/config/examples/JGAurora/A1/Configuration_adv.h +++ b/config/examples/JGAurora/A1/Configuration_adv.h @@ -1966,21 +1966,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1989,7 +1989,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/JGAurora/A5/Configuration_adv.h b/config/examples/JGAurora/A5/Configuration_adv.h index 40bf580297..4dff1b2db3 100644 --- a/config/examples/JGAurora/A5/Configuration_adv.h +++ b/config/examples/JGAurora/A5/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/JGAurora/A5S/Configuration_adv.h b/config/examples/JGAurora/A5S/Configuration_adv.h index 9e2338339b..cb33f28ab2 100644 --- a/config/examples/JGAurora/A5S/Configuration_adv.h +++ b/config/examples/JGAurora/A5S/Configuration_adv.h @@ -1966,21 +1966,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1989,7 +1989,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/JGAurora/Magic/Configuration_adv.h b/config/examples/JGAurora/Magic/Configuration_adv.h index 56289ff86a..a591c21d4a 100644 --- a/config/examples/JGAurora/Magic/Configuration_adv.h +++ b/config/examples/JGAurora/Magic/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Kingroon/KP3/Configuration_adv.h b/config/examples/Kingroon/KP3/Configuration_adv.h index 38d7794048..0da219bce4 100644 --- a/config/examples/Kingroon/KP3/Configuration_adv.h +++ b/config/examples/Kingroon/KP3/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Labists/ET4/Configuration_adv.h b/config/examples/Labists/ET4/Configuration_adv.h index 07f88d7273..4be4e1048d 100644 --- a/config/examples/Labists/ET4/Configuration_adv.h +++ b/config/examples/Labists/ET4/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/MBot/Cube/Configuration_adv.h b/config/examples/MBot/Cube/Configuration_adv.h index 0ef69c26fa..02c3cae28e 100644 --- a/config/examples/MBot/Cube/Configuration_adv.h +++ b/config/examples/MBot/Cube/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/MakerFarm/Pegasus 12/Configuration_adv.h b/config/examples/MakerFarm/Pegasus 12/Configuration_adv.h index 03ea1bb7df..f1c1be5399 100644 --- a/config/examples/MakerFarm/Pegasus 12/Configuration_adv.h +++ b/config/examples/MakerFarm/Pegasus 12/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/MakerParts/Configuration_adv.h b/config/examples/MakerParts/Configuration_adv.h index 8423655a13..3d42f530f6 100644 --- a/config/examples/MakerParts/Configuration_adv.h +++ b/config/examples/MakerParts/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Malyan/M150/Configuration_adv.h b/config/examples/Malyan/M150/Configuration_adv.h index d3ee967295..e8d057167c 100644 --- a/config/examples/Malyan/M150/Configuration_adv.h +++ b/config/examples/Malyan/M150/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Malyan/M200/Configuration_adv.h b/config/examples/Malyan/M200/Configuration_adv.h index 8685a6c98b..03e20b4197 100644 --- a/config/examples/Malyan/M200/Configuration_adv.h +++ b/config/examples/Malyan/M200/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Micromake/C1/enhanced/Configuration_adv.h b/config/examples/Micromake/C1/enhanced/Configuration_adv.h index 34473fe351..a91a217281 100644 --- a/config/examples/Micromake/C1/enhanced/Configuration_adv.h +++ b/config/examples/Micromake/C1/enhanced/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Mks/Robin/Configuration_adv.h b/config/examples/Mks/Robin/Configuration_adv.h index 0f71e23a95..6337e6d8a6 100644 --- a/config/examples/Mks/Robin/Configuration_adv.h +++ b/config/examples/Mks/Robin/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Mks/Sbase/Configuration_adv.h b/config/examples/Mks/Sbase/Configuration_adv.h index 51de6041a3..56e23da40e 100644 --- a/config/examples/Mks/Sbase/Configuration_adv.h +++ b/config/examples/Mks/Sbase/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Modix/Big60/Configuration_adv.h b/config/examples/Modix/Big60/Configuration_adv.h index 4292d1c4eb..4a0cb5cc2a 100644 --- a/config/examples/Modix/Big60/Configuration_adv.h +++ b/config/examples/Modix/Big60/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Nextion/Configuration_adv.h b/config/examples/Nextion/Configuration_adv.h index 21102be267..9e3c672868 100644 --- a/config/examples/Nextion/Configuration_adv.h +++ b/config/examples/Nextion/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Ortur 4/Configuration_adv.h b/config/examples/Ortur 4/Configuration_adv.h index 06a214e969..658f967449 100644 --- a/config/examples/Ortur 4/Configuration_adv.h +++ b/config/examples/Ortur 4/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Prusa/MK3/Configuration_adv.h b/config/examples/Prusa/MK3/Configuration_adv.h index 40ec619737..a78478029f 100644 --- a/config/examples/Prusa/MK3/Configuration_adv.h +++ b/config/examples/Prusa/MK3/Configuration_adv.h @@ -1936,21 +1936,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1959,7 +1959,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Prusa/MK3S-BigTreeTech-BTT002/Configuration_adv.h b/config/examples/Prusa/MK3S-BigTreeTech-BTT002/Configuration_adv.h index a5c3b94f59..ae17c2edf7 100644 --- a/config/examples/Prusa/MK3S-BigTreeTech-BTT002/Configuration_adv.h +++ b/config/examples/Prusa/MK3S-BigTreeTech-BTT002/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Qidi/Qidi 1/Configuration_adv.h b/config/examples/Qidi/Qidi 1/Configuration_adv.h index 82d49ddc28..8a87e81efc 100644 --- a/config/examples/Qidi/Qidi 1/Configuration_adv.h +++ b/config/examples/Qidi/Qidi 1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Raiscube/A8r/Configuration_adv.h b/config/examples/Raiscube/A8r/Configuration_adv.h index 0652b82a70..51839b1df1 100644 --- a/config/examples/Raiscube/A8r/Configuration_adv.h +++ b/config/examples/Raiscube/A8r/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/RapideLite/RL200/Configuration_adv.h b/config/examples/RapideLite/RL200/Configuration_adv.h index 6716a1b20f..a95915a1be 100644 --- a/config/examples/RapideLite/RL200/Configuration_adv.h +++ b/config/examples/RapideLite/RL200/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Renkforce/RF100/Configuration_adv.h b/config/examples/Renkforce/RF100/Configuration_adv.h index 6aacbd6f61..c61be9135c 100644 --- a/config/examples/Renkforce/RF100/Configuration_adv.h +++ b/config/examples/Renkforce/RF100/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Renkforce/RF100XL/Configuration_adv.h b/config/examples/Renkforce/RF100XL/Configuration_adv.h index 6aacbd6f61..c61be9135c 100644 --- a/config/examples/Renkforce/RF100XL/Configuration_adv.h +++ b/config/examples/Renkforce/RF100XL/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Renkforce/RF100v2/Configuration_adv.h b/config/examples/Renkforce/RF100v2/Configuration_adv.h index 6aacbd6f61..c61be9135c 100644 --- a/config/examples/Renkforce/RF100v2/Configuration_adv.h +++ b/config/examples/Renkforce/RF100v2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/RigidBot/Configuration_adv.h b/config/examples/RigidBot/Configuration_adv.h index 5438201c7a..5dfa004b41 100644 --- a/config/examples/RigidBot/Configuration_adv.h +++ b/config/examples/RigidBot/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/SCARA/MP_SCARA/Configuration_adv.h b/config/examples/SCARA/MP_SCARA/Configuration_adv.h index 55ffb02f70..cd4d684f67 100644 --- a/config/examples/SCARA/MP_SCARA/Configuration_adv.h +++ b/config/examples/SCARA/MP_SCARA/Configuration_adv.h @@ -1958,21 +1958,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1981,7 +1981,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/SCARA/Morgan/Configuration_adv.h b/config/examples/SCARA/Morgan/Configuration_adv.h index 2bf886a294..2af8ed741d 100644 --- a/config/examples/SCARA/Morgan/Configuration_adv.h +++ b/config/examples/SCARA/Morgan/Configuration_adv.h @@ -1958,21 +1958,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1981,7 +1981,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h b/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h index df223d233a..b38cec9d6d 100644 --- a/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h +++ b/config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Sanguinololu/Configuration_adv.h b/config/examples/Sanguinololu/Configuration_adv.h index 732acc2504..e1ecd3f03f 100644 --- a/config/examples/Sanguinololu/Configuration_adv.h +++ b/config/examples/Sanguinololu/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Sovol/SV-01/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h b/config/examples/Sovol/SV-01/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h index 3c519d899f..686707e848 100644 --- a/config/examples/Sovol/SV-01/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h +++ b/config/examples/Sovol/SV-01/BigTreeTech SKR Mini E3 2.0/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Sovol/SV-01/CrealityV22/Configuration_adv.h b/config/examples/Sovol/SV-01/CrealityV22/Configuration_adv.h index 4ec0201896..54ec6ef3ec 100644 --- a/config/examples/Sovol/SV-01/CrealityV22/Configuration_adv.h +++ b/config/examples/Sovol/SV-01/CrealityV22/Configuration_adv.h @@ -1959,21 +1959,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1982,7 +1982,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Sovol/SV-01/CrealityV221/Configuration_adv.h b/config/examples/Sovol/SV-01/CrealityV221/Configuration_adv.h index 9e644f2d26..89e26cea8b 100644 --- a/config/examples/Sovol/SV-01/CrealityV221/Configuration_adv.h +++ b/config/examples/Sovol/SV-01/CrealityV221/Configuration_adv.h @@ -1959,21 +1959,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1982,7 +1982,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Sunlu/S8/Configuration_adv.h b/config/examples/Sunlu/S8/Configuration_adv.h index 2e00c1969b..7fa25cc0e1 100644 --- a/config/examples/Sunlu/S8/Configuration_adv.h +++ b/config/examples/Sunlu/S8/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/TPARA/AXEL_TPARA/Configuration_adv.h b/config/examples/TPARA/AXEL_TPARA/Configuration_adv.h index ac4dc3868e..34e7fcf3cc 100644 --- a/config/examples/TPARA/AXEL_TPARA/Configuration_adv.h +++ b/config/examples/TPARA/AXEL_TPARA/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tevo/Michelangelo/Configuration_adv.h b/config/examples/Tevo/Michelangelo/Configuration_adv.h index 032631804d..5e7db6119b 100644 --- a/config/examples/Tevo/Michelangelo/Configuration_adv.h +++ b/config/examples/Tevo/Michelangelo/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tevo/Nereus/Configuration_adv.h b/config/examples/Tevo/Nereus/Configuration_adv.h index 8fc7ac906d..c054e9beb8 100644 --- a/config/examples/Tevo/Nereus/Configuration_adv.h +++ b/config/examples/Tevo/Nereus/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tevo/Tarantula Pro/Configuration_adv.h b/config/examples/Tevo/Tarantula Pro/Configuration_adv.h index 08f6741265..f00cb47b7f 100644 --- a/config/examples/Tevo/Tarantula Pro/Configuration_adv.h +++ b/config/examples/Tevo/Tarantula Pro/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tevo/Tornado/V1 (MKS Base)/Configuration_adv.h b/config/examples/Tevo/Tornado/V1 (MKS Base)/Configuration_adv.h index b34eb80050..b67ef7a805 100644 --- a/config/examples/Tevo/Tornado/V1 (MKS Base)/Configuration_adv.h +++ b/config/examples/Tevo/Tornado/V1 (MKS Base)/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tevo/Tornado/V2 (MKS GEN-L)/Configuration_adv.h b/config/examples/Tevo/Tornado/V2 (MKS GEN-L)/Configuration_adv.h index b34eb80050..b67ef7a805 100644 --- a/config/examples/Tevo/Tornado/V2 (MKS GEN-L)/Configuration_adv.h +++ b/config/examples/Tevo/Tornado/V2 (MKS GEN-L)/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/TheBorg/Configuration_adv.h b/config/examples/TheBorg/Configuration_adv.h index ac068edade..967d975843 100644 --- a/config/examples/TheBorg/Configuration_adv.h +++ b/config/examples/TheBorg/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/TinyBoy2/Configuration_adv.h b/config/examples/TinyBoy2/Configuration_adv.h index 2d62fc55ff..a0057de989 100644 --- a/config/examples/TinyBoy2/Configuration_adv.h +++ b/config/examples/TinyBoy2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tronxy/X3A/Configuration_adv.h b/config/examples/Tronxy/X3A/Configuration_adv.h index 26d8203700..a409843bb5 100644 --- a/config/examples/Tronxy/X3A/Configuration_adv.h +++ b/config/examples/Tronxy/X3A/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tronxy/X5S-2E/Configuration_adv.h b/config/examples/Tronxy/X5S-2E/Configuration_adv.h index 22c85cc392..5b4b9ce499 100644 --- a/config/examples/Tronxy/X5S-2E/Configuration_adv.h +++ b/config/examples/Tronxy/X5S-2E/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Tronxy/X5SA/Configuration_adv.h b/config/examples/Tronxy/X5SA/Configuration_adv.h index bf96e38ffc..567967d2c9 100644 --- a/config/examples/Tronxy/X5SA/Configuration_adv.h +++ b/config/examples/Tronxy/X5SA/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Two Trees/BlueR Plus/Configuration_adv.h b/config/examples/Two Trees/BlueR Plus/Configuration_adv.h index 8e544b6689..c28ac46d04 100644 --- a/config/examples/Two Trees/BlueR Plus/Configuration_adv.h +++ b/config/examples/Two Trees/BlueR Plus/Configuration_adv.h @@ -1962,21 +1962,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1985,7 +1985,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Two Trees/BlueR/BlueR V1/Configuration_adv.h b/config/examples/Two Trees/BlueR/BlueR V1/Configuration_adv.h index 4dc11f7f93..26631fe9ba 100644 --- a/config/examples/Two Trees/BlueR/BlueR V1/Configuration_adv.h +++ b/config/examples/Two Trees/BlueR/BlueR V1/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Two Trees/BlueR/BlueR V2/Configuration_adv.h b/config/examples/Two Trees/BlueR/BlueR V2/Configuration_adv.h index 4dc11f7f93..26631fe9ba 100644 --- a/config/examples/Two Trees/BlueR/BlueR V2/Configuration_adv.h +++ b/config/examples/Two Trees/BlueR/BlueR V2/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Two Trees/BlueR/BlueR V3/Configuration_adv.h b/config/examples/Two Trees/BlueR/BlueR V3/Configuration_adv.h index 4dc11f7f93..26631fe9ba 100644 --- a/config/examples/Two Trees/BlueR/BlueR V3/Configuration_adv.h +++ b/config/examples/Two Trees/BlueR/BlueR V3/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Two Trees/Sapphire Plus/Sapphire Plus V2/Configuration_adv.h b/config/examples/Two Trees/Sapphire Plus/Sapphire Plus V2/Configuration_adv.h index 520174f249..9bd7906ca1 100644 --- a/config/examples/Two Trees/Sapphire Plus/Sapphire Plus V2/Configuration_adv.h +++ b/config/examples/Two Trees/Sapphire Plus/Sapphire Plus V2/Configuration_adv.h @@ -1967,21 +1967,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1990,7 +1990,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Two Trees/Sapphire Pro/Configuration_adv.h b/config/examples/Two Trees/Sapphire Pro/Configuration_adv.h index f6b0e85b64..f61965e4aa 100644 --- a/config/examples/Two Trees/Sapphire Pro/Configuration_adv.h +++ b/config/examples/Two Trees/Sapphire Pro/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/UltiMachine/Archim1/Configuration_adv.h b/config/examples/UltiMachine/Archim1/Configuration_adv.h index 1309a3d59b..34d50276e4 100644 --- a/config/examples/UltiMachine/Archim1/Configuration_adv.h +++ b/config/examples/UltiMachine/Archim1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/UltiMachine/Archim2/Configuration_adv.h b/config/examples/UltiMachine/Archim2/Configuration_adv.h index 5ecf26c64c..ac7af8423f 100644 --- a/config/examples/UltiMachine/Archim2/Configuration_adv.h +++ b/config/examples/UltiMachine/Archim2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Ultimaker/Ultimaker Original (1.5.7)/Configuration_adv.h b/config/examples/Ultimaker/Ultimaker Original (1.5.7)/Configuration_adv.h index 679b10e226..5683404e3f 100644 --- a/config/examples/Ultimaker/Ultimaker Original (1.5.7)/Configuration_adv.h +++ b/config/examples/Ultimaker/Ultimaker Original (1.5.7)/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Ultimaker/Ultimaker Original Plus (2.1.1)/Configuration_adv.h b/config/examples/Ultimaker/Ultimaker Original Plus (2.1.1)/Configuration_adv.h index 7deec53313..ff2d749660 100644 --- a/config/examples/Ultimaker/Ultimaker Original Plus (2.1.1)/Configuration_adv.h +++ b/config/examples/Ultimaker/Ultimaker Original Plus (2.1.1)/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/VORONDesign/Configuration_adv.h b/config/examples/VORONDesign/Configuration_adv.h index fe24d05c87..d30052de1f 100644 --- a/config/examples/VORONDesign/Configuration_adv.h +++ b/config/examples/VORONDesign/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Velleman/K8200/Configuration_adv.h b/config/examples/Velleman/K8200/Configuration_adv.h index b3765c71ca..c2115aefe9 100644 --- a/config/examples/Velleman/K8200/Configuration_adv.h +++ b/config/examples/Velleman/K8200/Configuration_adv.h @@ -1974,21 +1974,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1997,7 +1997,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Velleman/K8400/Dual-head/Configuration_adv.h b/config/examples/Velleman/K8400/Dual-head/Configuration_adv.h index f8ff47f69f..386ca5f70c 100644 --- a/config/examples/Velleman/K8400/Dual-head/Configuration_adv.h +++ b/config/examples/Velleman/K8400/Dual-head/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Velleman/K8400/Single-head/Configuration_adv.h b/config/examples/Velleman/K8400/Single-head/Configuration_adv.h index f8ff47f69f..386ca5f70c 100644 --- a/config/examples/Velleman/K8400/Single-head/Configuration_adv.h +++ b/config/examples/Velleman/K8400/Single-head/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/WASP/PowerWASP/Configuration_adv.h b/config/examples/WASP/PowerWASP/Configuration_adv.h index bdab466b22..a284a950ed 100644 --- a/config/examples/WASP/PowerWASP/Configuration_adv.h +++ b/config/examples/WASP/PowerWASP/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Wanhao/Duplicator 4S/Configuration_adv.h b/config/examples/Wanhao/Duplicator 4S/Configuration_adv.h index 984a479fdc..beadd325bb 100644 --- a/config/examples/Wanhao/Duplicator 4S/Configuration_adv.h +++ b/config/examples/Wanhao/Duplicator 4S/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Wanhao/Duplicator 6/Configuration_adv.h b/config/examples/Wanhao/Duplicator 6/Configuration_adv.h index b125d4ef92..d743d0b953 100644 --- a/config/examples/Wanhao/Duplicator 6/Configuration_adv.h +++ b/config/examples/Wanhao/Duplicator 6/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Wanhao/Duplicator i3 2.1/Configuration_adv.h b/config/examples/Wanhao/Duplicator i3 2.1/Configuration_adv.h index 4a32310458..331e9b363b 100644 --- a/config/examples/Wanhao/Duplicator i3 2.1/Configuration_adv.h +++ b/config/examples/Wanhao/Duplicator i3 2.1/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Wanhao/Duplicator i3 Mini/Configuration_adv.h b/config/examples/Wanhao/Duplicator i3 Mini/Configuration_adv.h index 117042cd44..ea008f82e3 100644 --- a/config/examples/Wanhao/Duplicator i3 Mini/Configuration_adv.h +++ b/config/examples/Wanhao/Duplicator i3 Mini/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Wanhao/Duplicator i3 Plus/Configuration_adv.h b/config/examples/Wanhao/Duplicator i3 Plus/Configuration_adv.h index 0f71e23a95..6337e6d8a6 100644 --- a/config/examples/Wanhao/Duplicator i3 Plus/Configuration_adv.h +++ b/config/examples/Wanhao/Duplicator i3 Plus/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Weistek/wt150/Configuration_adv.h b/config/examples/Weistek/wt150/Configuration_adv.h index 9912414271..1170d25feb 100644 --- a/config/examples/Weistek/wt150/Configuration_adv.h +++ b/config/examples/Weistek/wt150/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Zonestar/P802M/Configuration_adv.h b/config/examples/Zonestar/P802M/Configuration_adv.h index 4867c4a7fb..b1af1315cc 100644 --- a/config/examples/Zonestar/P802M/Configuration_adv.h +++ b/config/examples/Zonestar/P802M/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/Zonestar/P802QR2/BigTreeTech SKR 1.4 Turbo (A4988)/Configuration_adv.h b/config/examples/Zonestar/P802QR2/BigTreeTech SKR 1.4 Turbo (A4988)/Configuration_adv.h index 18a261f79c..1a893b2794 100755 --- a/config/examples/Zonestar/P802QR2/BigTreeTech SKR 1.4 Turbo (A4988)/Configuration_adv.h +++ b/config/examples/Zonestar/P802QR2/BigTreeTech SKR 1.4 Turbo (A4988)/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Anycubic/Kossel Linear Plus/Configuration_adv.h b/config/examples/delta/Anycubic/Kossel Linear Plus/Configuration_adv.h index b7ca348153..48743c3d6d 100644 --- a/config/examples/delta/Anycubic/Kossel Linear Plus/Configuration_adv.h +++ b/config/examples/delta/Anycubic/Kossel Linear Plus/Configuration_adv.h @@ -1964,21 +1964,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1987,7 +1987,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Anycubic/Kossel/Configuration_adv.h b/config/examples/delta/Anycubic/Kossel/Configuration_adv.h index 8c0283d886..4359d79f42 100644 --- a/config/examples/delta/Anycubic/Kossel/Configuration_adv.h +++ b/config/examples/delta/Anycubic/Kossel/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Anycubic/Predator/Configuration_adv.h b/config/examples/delta/Anycubic/Predator/Configuration_adv.h index a444b81ebd..9463a05052 100644 --- a/config/examples/delta/Anycubic/Predator/Configuration_adv.h +++ b/config/examples/delta/Anycubic/Predator/Configuration_adv.h @@ -1964,21 +1964,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1987,7 +1987,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Dreammaker/Overlord/Configuration_adv.h b/config/examples/delta/Dreammaker/Overlord/Configuration_adv.h index 8afd327d96..44d8663f6b 100644 --- a/config/examples/delta/Dreammaker/Overlord/Configuration_adv.h +++ b/config/examples/delta/Dreammaker/Overlord/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Dreammaker/Overlord_Pro/Configuration_adv.h b/config/examples/delta/Dreammaker/Overlord_Pro/Configuration_adv.h index 8afd327d96..44d8663f6b 100644 --- a/config/examples/delta/Dreammaker/Overlord_Pro/Configuration_adv.h +++ b/config/examples/delta/Dreammaker/Overlord_Pro/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/FLSUN/Q5-nano_v1/Configuration_adv.h b/config/examples/delta/FLSUN/Q5-nano_v1/Configuration_adv.h index e2e7b6ed64..26251f96f3 100644 --- a/config/examples/delta/FLSUN/Q5-nano_v1/Configuration_adv.h +++ b/config/examples/delta/FLSUN/Q5-nano_v1/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/FLSUN/QQ-S/Configuration_adv.h b/config/examples/delta/FLSUN/QQ-S/Configuration_adv.h index ab4a4931e9..24891149f5 100644 --- a/config/examples/delta/FLSUN/QQ-S/Configuration_adv.h +++ b/config/examples/delta/FLSUN/QQ-S/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/FLSUN/QQS-Pro/Configuration_adv.h b/config/examples/delta/FLSUN/QQS-Pro/Configuration_adv.h index 38fdff8099..bc168f0c73 100644 --- a/config/examples/delta/FLSUN/QQS-Pro/Configuration_adv.h +++ b/config/examples/delta/FLSUN/QQS-Pro/Configuration_adv.h @@ -1964,21 +1964,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1987,7 +1987,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h b/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h index b66d3cf97e..455529dfdd 100644 --- a/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h +++ b/config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/FLSUN/kossel/Configuration_adv.h b/config/examples/delta/FLSUN/kossel/Configuration_adv.h index b66d3cf97e..455529dfdd 100644 --- a/config/examples/delta/FLSUN/kossel/Configuration_adv.h +++ b/config/examples/delta/FLSUN/kossel/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h b/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h index d8d8109b39..ede06e1f78 100644 --- a/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h +++ b/config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Geeetech/G2/Configuration_adv.h b/config/examples/delta/Geeetech/G2/Configuration_adv.h index 0d5bcb1aa9..0f6ddcf24e 100644 --- a/config/examples/delta/Geeetech/G2/Configuration_adv.h +++ b/config/examples/delta/Geeetech/G2/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Geeetech/G2Pro/Configuration_adv.h b/config/examples/delta/Geeetech/G2Pro/Configuration_adv.h index 7c0a3b14c1..c0a2b658bd 100644 --- a/config/examples/delta/Geeetech/G2Pro/Configuration_adv.h +++ b/config/examples/delta/Geeetech/G2Pro/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Geeetech/G2S/Configuration_adv.h b/config/examples/delta/Geeetech/G2S/Configuration_adv.h index 7c0a3b14c1..c0a2b658bd 100644 --- a/config/examples/delta/Geeetech/G2S/Configuration_adv.h +++ b/config/examples/delta/Geeetech/G2S/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Geeetech/G2SPro/Configuration_adv.h b/config/examples/delta/Geeetech/G2SPro/Configuration_adv.h index 7c0a3b14c1..c0a2b658bd 100644 --- a/config/examples/delta/Geeetech/G2SPro/Configuration_adv.h +++ b/config/examples/delta/Geeetech/G2SPro/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h b/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h index 407012fd84..4f834346cf 100644 --- a/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h +++ b/config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Hatchbox_Alpha/Configuration_adv.h b/config/examples/delta/Hatchbox_Alpha/Configuration_adv.h index f6de0cae23..ef42d1422a 100644 --- a/config/examples/delta/Hatchbox_Alpha/Configuration_adv.h +++ b/config/examples/delta/Hatchbox_Alpha/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/MKS/SBASE/Configuration_adv.h b/config/examples/delta/MKS/SBASE/Configuration_adv.h index ecb7980672..ab24c848c9 100644 --- a/config/examples/delta/MKS/SBASE/Configuration_adv.h +++ b/config/examples/delta/MKS/SBASE/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Malyan M300/Configuration_adv.h b/config/examples/delta/Malyan M300/Configuration_adv.h index 04939e9092..ecbbe30fe8 100644 --- a/config/examples/delta/Malyan M300/Configuration_adv.h +++ b/config/examples/delta/Malyan M300/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/Tevo Little Monster/Configuration_adv.h b/config/examples/delta/Tevo Little Monster/Configuration_adv.h index a17ecc7ef4..50d213f3b5 100644 --- a/config/examples/delta/Tevo Little Monster/Configuration_adv.h +++ b/config/examples/delta/Tevo Little Monster/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/generic/Configuration_adv.h b/config/examples/delta/generic/Configuration_adv.h index d8d8109b39..ede06e1f78 100644 --- a/config/examples/delta/generic/Configuration_adv.h +++ b/config/examples/delta/generic/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/kossel_clear/Configuration_adv.h b/config/examples/delta/kossel_clear/Configuration_adv.h index 9e85f56075..0a0b28a1b3 100644 --- a/config/examples/delta/kossel_clear/Configuration_adv.h +++ b/config/examples/delta/kossel_clear/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/delta/kossel_xl/Configuration_adv.h b/config/examples/delta/kossel_xl/Configuration_adv.h index 12fb57a3df..f2bf9bdef9 100644 --- a/config/examples/delta/kossel_xl/Configuration_adv.h +++ b/config/examples/delta/kossel_xl/Configuration_adv.h @@ -1963,21 +1963,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1986,7 +1986,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/gCreate/gMax1.5+/Configuration_adv.h b/config/examples/gCreate/gMax1.5+/Configuration_adv.h index fca8b985cf..6487b8c430 100644 --- a/config/examples/gCreate/gMax1.5+/Configuration_adv.h +++ b/config/examples/gCreate/gMax1.5+/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/makibox/Configuration_adv.h b/config/examples/makibox/Configuration_adv.h index 14cd87a8dd..3609c9090b 100644 --- a/config/examples/makibox/Configuration_adv.h +++ b/config/examples/makibox/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0] diff --git a/config/examples/tvrrug/Round2/Configuration_adv.h b/config/examples/tvrrug/Round2/Configuration_adv.h index 048e229c21..a1dea85f22 100644 --- a/config/examples/tvrrug/Round2/Configuration_adv.h +++ b/config/examples/tvrrug/Round2/Configuration_adv.h @@ -1961,21 +1961,21 @@ //#define USE_TEMP_EXT_COMPENSATION // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START - // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples. + // (e.g., 30), in steps of PTC_SAMPLE_RES (e.g., 5) with PTC_SAMPLE_COUNT (e.g., 10) samples. - //#define PTC_SAMPLE_START 30.0f - //#define PTC_SAMPLE_RES 5.0f - //#define PTC_SAMPLE_COUNT 10U + //#define PTC_SAMPLE_START 30 // (°C) + //#define PTC_SAMPLE_RES 5 // (°C) + //#define PTC_SAMPLE_COUNT 10 // Bed temperature calibration builds a similar table. - //#define BTC_SAMPLE_START 60.0f - //#define BTC_SAMPLE_RES 5.0f - //#define BTC_SAMPLE_COUNT 10U + //#define BTC_SAMPLE_START 60 // (°C) + //#define BTC_SAMPLE_RES 5 // (°C) + //#define BTC_SAMPLE_COUNT 10 // The temperature the probe should be at while taking measurements during bed temperature // calibration. - //#define BTC_PROBE_TEMP 30.0f + //#define BTC_PROBE_TEMP 30 // (°C) // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster. // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851. @@ -1984,7 +1984,7 @@ // Height to raise the Z-probe between heating and taking the next measurement. Some probes // may fail to untrigger if they have been triggered for a long time, which can be solved by // increasing the height the probe is raised to. - //#define PTC_PROBE_RAISE 15U + //#define PTC_PROBE_RAISE 15 // If the probe is outside of the defined range, use linear extrapolation using the closest // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0]