@ -23,6 +23,9 @@
#error "Don't build with import-2.0.x configurations!"
#error "Use the 'bugfix...' or 'release...' configurations matching your Marlin version."
// Overlord Pro needs larger PSU than stock PSU. Uncomment `#define OVERLORD_PRO_UPGRADED_PSU` to enable heated bed. See README.md for more details.
//#define OVERLORD_PRO_UPGRADED_PSU
/**
* Configuration.h
*
@ -539,7 +542,11 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_6 0
#define TEMP_SENSOR_7 0
#define TEMP_SENSOR_BED 1
#ifdef OVERLORD_PRO_UPGRADED_PSU
#define TEMP_SENSOR_BED 1
#else
#define TEMP_SENSOR_BED 0
#endif
#define TEMP_SENSOR_PROBE 0
#define TEMP_SENSOR_CHAMBER 0
#define TEMP_SENSOR_COOLER 0
@ -721,18 +728,6 @@
* so don't use it unless you are OK with PWM on your bed. (See the comment on enabling PIDTEMPBED)
*/
#define MAX_BED_POWER 255 // limits duty cycle to bed; 255=full current
#if TEMP_SENSOR_BED != 0
/*
* For Overlord Pro, the default PSU isn't powerful to run hotend/bed/etc.
* Problem is Hotend heater is 24V 60W, Bed is 24V 160W, Standard Overlord Pro PSU is 24V 220.8W
* Hotend and bed are PWMed to keep their average power less than the max power but they can both be on at the same time.
* If both are on at the same time, then there is no power available for anything else
* and power supply will shutdown if steppers are moving while both hotend and bed are on
* Recommend upgrade PSU
* A Meanwell RSP-500-24 works, a RSP-350-24 should work but has not been tested
*/
#error "Overlord Pro needs larger PSU than stock PSU, comment out this line if you have a larger PSU, otherwise set TEMP_SENSOR_BED to 0"