// Overlord Pro needs larger PSU than stock PSU. Uncomment `#define OVERLORD_PRO_UPGRADED_PSU` to enable heated bed. See README.md for more details.
//#define OVERLORD_PRO_UPGRADED_PSU
/**
* Configuration.h
*
@ -539,7 +542,11 @@
#define TEMP_SENSOR_5 0
#define TEMP_SENSOR_6 0
#define TEMP_SENSOR_7 0
#define TEMP_SENSOR_BED 1
#ifdef OVERLORD_PRO_UPGRADED_PSU
#define TEMP_SENSOR_BED 1
#else
#define TEMP_SENSOR_BED 0
#endif
#define TEMP_SENSOR_PROBE 0
#define TEMP_SENSOR_CHAMBER 0
#define TEMP_SENSOR_COOLER 0
@ -721,18 +728,6 @@
* so don't use it unless you are OK with PWM on your bed. (See the comment on enabling PIDTEMPBED)
*/
#define MAX_BED_POWER 255 // limits duty cycle to bed; 255=full current
#if TEMP_SENSOR_BED != 0
/*
* For Overlord Pro, the default PSU isn't powerful to run hotend/bed/etc.
* Problem is Hotend heater is 24V 60W, Bed is 24V 160W, Standard Overlord Pro PSU is 24V 220.8W
* Hotend and bed are PWMed to keep their average power less than the max power but they can both be on at the same time.
* If both are on at the same time, then there is no power available for anything else
* and power supply will shutdown if steppers are moving while both hotend and bed are on
* Recommend upgrade PSU
* A Meanwell RSP-500-24 works, a RSP-350-24 should work but has not been tested
*/
#error "Overlord Pro needs larger PSU than stock PSU, comment out this line if you have a larger PSU, otherwise set TEMP_SENSOR_BED to 0"
#endif
#if ENABLED(PIDTEMPBED)
//#define MIN_BED_POWER 0

View file

@ -0,0 +1,15 @@
# Dreammaker Overlord Pro
Overlord Pro needs larger PSU than stock PSU. Uncomment `#define OVERLORD_PRO_UPGRADED_PSU` to enable heated bed.
## Details
The hotend heater is 24V 60W, bed is 24V 160W, standard Overlord Pro PSU is 24V 220.8W.
Hotend and bed are PWMed to keep their average power less than the max power but they can both be on at the same time.
If both are on at the same time, then there is no power available for anything else and power supply will shutdown if steppers are moving while both hotend and bed are on.
## Recommend PSU
A Meanwell RSP-500-24 works, a RSP-350-24 should work but has not been tested.